Extron electronic MAV PLUS SERIES Switch User Manual


 
4-19
CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Information requests (continued)
Request BME part number N
nn-nnn-nn
]
See appendix B for numbers.
Example:
N
60-768-41
]
CrossPoint 450 Plus 6464
with front panel controller.
N
There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which
is the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest
optional Extron firmware update, which is available at www.extron.com.
Query firmware version Q
X2)]
Example:
Q
1.23
]
The factory-installed
controller firmware version
is 1.23 (sample value only).
Query controller firmware
version (verbose)
0Q
X2)
-
X2!
-
X2!]
Provide a detailed status
of the Ethernet protocol
firmware, the controller
firmware, and any firmware
upgrade. The firmware that
is running is marked by
an asterisk (*). A caret (^)
indicates that the firmware
has a bad checksum or an
invalid load. ?.?? indicates
that firmware is not loaded.
Response description:
Ethernet protocol firmware version-controller firmware version-updated firmware version
]
Example:
0q
Ethernet protocol
firmware
Response:
Description
CrossPoint/MAV firmware version
1.23-0.14(0.20-64x64 Series -Wed, 22 Feb 2006 00:00:00 GMT)-0.25*(0.24-64x64 Series -Thu, 16 Mar 2006 16:39:21 GMT)
Updated firmware version
* indicates the version running Upload date and time
Request system status S
X2@
X2@
X2@
X2@
X2@
X2@
X2@
X2#
X2$
X2$
X#
X#]
Response description:
+5V•+3.3V•+2.5V•Fan voltage•-5V•-12V•+12V•Temp•Fan1 RPM•Fan2 RPM•Primary PS•Secondary PS
]
Example:
S
4.98•3.30•2.55•11.52•-5.21•-12.35•11.65•78.80•753•774•1•1
Fans receiving 11.52 V Secondary power supply is on and Ok
Fan 1 rotating at 753 RPM5V power system at 4.98V
N
If one of the variables is not applicable to a BME (such as fans for a video BME), the response for that variable is “---”.
N
X#
= Power supply status 0 = not OK 1 = OK
X2)
= Firmware version number to second decimal place (x.xx)
X2!
= Verbose firmware version-description-upload date/time
X2@
= Voltage Positive or negative voltage and magnitude
X2#
= Temperature Degrees Fahrenheit
X2$
= Fan speed RPM