Extron electronic MAV PLUS SERIES Switch User Manual


 
Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-30
Example 7: Saving a preset
In the following example, the current configuration is saved as a preset. The steps
show the front panel indications that result from your actions.
1
. Clear all selections: Press and release the Esc button.
C O N T R O L
PRESET
ENTER
ESCVIEW
Press the Esc button to clear all selections.
The button flashes once.
2. Select Save Preset mode: Press and hold the Preset button for approximately
2 seconds until it blinks.
PRESET PRESET
17 18 19
1 2 3
I
N
All input buttons with assigned
presets light.
If you then save the configuration
to a lit preset number, the
configuration data at that preset
location will be overwritten.
Press and hold the Preset button
until it blinks.
2 seconds
Lit
(Preset Assigned)
Unlit
(No Preset Assigned)
3. Select the preset: Press and release the input button for the desired preset.
C O N T R O L
PRESET
ENTER
ESC VIEW
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
I
N
The Enter button blinks to
indicate the need to save the
preset.
The Preset button continues
to blink.
Press and release the Input 1 button.
The button blinks to indicate that this
preset number is selected but not saved.
4. Confirm the change: Press and release the Enter button. The current
configuration is now stored in the selected memory location.
C O N T R O L
PRESET
ENTER
ESCVIEW
The Enter and Preset
buttons return to unlit or
background illumination.
Press the Enter button to
save the preset.
All input buttons and output
buttons return to unlit or
background illumination.