Extron electronic MAV PLUS SERIES Switch User Manual


 
HTML Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • HTML Operation
6-10
Email address fields
The eight Email Address fields identify the e-mail addresses of the personnel to
whom the CrossPoint or MAV switcher BME 0 e-mails notification of its failure and
repair status. Standard e-mail address conventions (nnnnn@xxx.com) apply.
The check boxes and drop boxes associated with each address field permit the
operator to specify criteria under which the BME will e-mail recipients. In the
associated Missing Inputs drop boxes, select the inputs to monitor for presence or
absence of a signal. Check the Fans and Power boxes to monitor the cooling and
power supplies. In the associated E-Mail Options drop box, select whether the
recipient is to be e-mailed of failures, fixes, or both; not notified; or be removed
from the e-mail list. The Suspend option is useful for temporarily removing
personnel from the e-mail list when they are unavailable, such as on travel or
vacation. Deleting an e-mail addressee and clicking the Submit button removes the
recipient from e-mail notification completely.
Firmware Upgrade page
The Firmware Upgrade page provides a way to replace the firmware that is coded
on each BME’s control board without taking the switcher out of service. Access the
Firmware Upgrade page (figure 6-8) by clicking the Firmware Upgrade link on the
System Settings page.
Passwords
System Settings
Refresh
Email settings
Figure 6-8 Firmware Upgrade page
Update the firmware for each BME as follows:
N
The Firmware Upgrade page is only for replacing the firmware that controls
all switcher operation. To insert your own custom HTML pages, see “File
Management Page”, on page 6-12.
1. Visit the Extron Web site, www.extron.com, select the CrossPoint 450 Plus/
MAV Plus product category, select the latest firmware installation package
(*.exe file) for the switcher, and download the file
. Note the folder to which you
save the firmware file.
2
. Run the executable (*.exe) file to decompress the firmware file.
3. Connect the PC to the matrix switcher BME via the switcher’s LAN port.
4. Access the matrix switcher BME using HTML pages.
5. Click the Configuration tab.