Fujitsu DX8100 S2/DX8700 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 10 Component Management
10.1 Component Status
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
685
Sensor Information
The real time and threshold values (Low/High) for the temperature, voltage, current, transmission
power, and received power are displayed in the Sensor Information.
When the information cannot be obtained, a "-" (hyphen) is displayed.
The target components for this information are FC that have SFPs from which information can be
obtained.
- Temperature
Present
The real time temperature of the SFP in the port is displayed.
- x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
Warning
- Low or High
The Warning threshold (Low/High) for the temperature of the SFP in the port is displayed.
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
Alarm
- Low or High
The Alarm threshold (Low/High) for the temperature of the SFP in the port is displayed.
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
- Voltage
Present
The real time voltage of the SFP in the port is displayed.
- x V (x: 0.00 to 6.55)
Warning
- Low or High
The Warning threshold (Low/High) for the voltage of the SFP in the port is displayed.
x V (x: 0.00 to 6.55)
Alarm
- Low or High
The Alarm threshold (Low/High) for the voltage of the SFP in the port is displayed.
x V (x: 0.00 to 6.55)
An SFP is regarded as being in Warning status when the real time value is lower than the Warning
threshold (Low) and higher than the Alarm threshold (Low).
An SFP is regarded as being in Warning status when the real time value is higher than the Warning
threshold (High) and lower than the Alarm threshold (High).
An SFP is regarded as being in Alarm status when the real time value is lower than the Alarm