11.2.9.3 Export/Delete Log
This function exports and saves the ETERNUS DX Disk storage system maintenance information (log) in
accordance with user-specified time settings.
An exported log can be stored on a floppy disk or hard disk, or sent by E-mail.
Also, users can select a log segment size to suit the destination it is to be saved.
The maintenance information to be exported
Log to be exported includes an "internal log" and "configuration information".
- Internal log
Detected errors, warnings, and traces
- Configuration definition information
Configuration information exported from the ETERNUS DX Disk storage system
The procedure to export log is as follows:
Procedure
1 Click [Export/Delete Log] in [Action].
2 Set the detailed information for exporting a log, and click the [Export] button.
Specify Time Range
To specify a time range for exporting logs, select "Yes". Select "No" if not specifying. To export logs
from the last 24 hours, select the "Last 24 hours".
Start Time
When a time range is to be specified, specify the date and time to start exporting logs.
- YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Date (01 - 31), hh: Hour (00
- 23), mm: Minute (00 - 59), ss: Second (00 - 59))
End Time
When a time range is to be specified, specify the date and time to finish exporting logs.
- YYYY-MM-DD hh:mm:ss (YYYY: Year (AD), MM: Month (01 - 12), DD: Date (01 - 31), hh: Hour (00
- 23), mm: Minute (00 - 59), ss: Second (00 - 59))
Include I/O Module log
When exporting the I/O module logs, select "Yes". When not exporting, select "No".
Log File Size
Select the log file size (segment size) when saving the exported log from the following.
- Non-segmentation
- 4.27MB
- 1.44MB (Floppy Disk)
- 640KB (E-Mail)
The internal log and configuration information cannot be exported separately.
When exporting of the log has been completed, save the log file immediately.
The various pieces of maintenance information are combined together, compressed, and then
segmented into the user specified segment size before being exported.