Fujitsu DX8100 S2/DX8700 S2 Computer Drive User Manual


  Open as PDF
of 1066
 
Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
Copyright 2013 FUJITSU LIMITED P2X0-1090-10ENZ0
756
7 Click the [OK] button.
The network environment setting starts.
8 Click the [Done] button to return to the [Network] screen.
End of procedure
Note the following points when specifying an IP address:
- IP addresses must be specified with the IPv6 format. Refer to "IPv6 Address Notation (Setup
Network Environment)" (page 757) for details
- The connect IP address of the RMT port must be in a different subnetwork from the MNT port
- Specify the connect IP address of the Slave CM when connecting to the Slave CM The connect IP
address of the Slave CM must be in the same subnetwork as the Master CM
- Specify the IP address of "Gateway" when allowing access from outside of the subnetwork The
IP address must be in the same subnetwork as the port
- For "Allowed IP List", specify the IP address or the network address that allows access to the
ETERNUS DX Disk storage system. These settings are not required for access from the network
address (same subnetwork) which the ETERNUS DX Disk storage system belongs to
Click the [Clear] button to delete setting parameters
When using the ETERNUS DX80 S2/DX90 S2, the MNT port setting cannot be deleted
When using the ETERNUS DX410 S2/DX440 S2 or the ETERNUS DX8100 S2/DX8700 S2, the FST port
setting cannot be deleted
Device management operation cannot be continued if the IP address of the ETERNUS DX Disk storage
system has been changed. Logging in again with the new IP address is required.