HP (Hewlett-Packard) 30 HP30 Projector User Manual


 
Chapter 6 - Parameter Description [I/O]
6-50
[Auto-A]
This mode will allow the inverter to operate automatically
followed by its pre-programmed sequence. According to
this sequence, eight different steps of Frequency,
Transient Time, Steady Speed time and Motor Direction
can be initiated with only a single multi-function input
contact closure (I/O-12 ~ I/O-14). The sequence and steps
are set in I/O-51 ~ I/O-84.
Step
Frequency
Parameter
Code
Speed-H
(P3)
Speed-M
(P2)
Speed-L
(P1)
Sequence 1 0 0 1
Sequence 2 0 1 0
Sequence 3 1 0 0
Sequence 4 0 1 1
Sequence 5
I/O-50 ~
I/O-84
1 0 1
0: OFF, 1: ON
[Example 1 of ‘Auto-A’ operation]
[Example 2 of ‘Auto-A’ operation]
[AUTO B]
This mode can be also used to program up to 8 different
steps as Auto A. However, to switch from one step to
another, an external contact closure set to ‘Go step’ is
required.
[Example of ‘Auto-B’ operation]
Output Frequency
Time
Seq1 / 2F
Seq1 / 1F
Seq1 / 3F
1T 1S 2T 2S 3T 3S
1D
(
Forward
)
2D
(
Forward
)
3D
(
Reverse
)
P1-CM
‘SEQ-L’
ON
Time
P1-CM
‘SEQ-L’
ON
Output Frequency
Time
ON
Time
P2-CM
‘SEQ-M’
SEQ1 / 2F
SEQ2 / 2F
SEQ1 / 1F
SEQ3 / 2F
SEQ3 / 1F
Sequence 1
Sequence 3 Sequence 2
Time
P1-CM
‘SEQ-L’
ON
Output Frequency
Time
ON
Time
ON
Time
P2-CM
‘SEQ-M’
P3-CM
‘Go step’
ON ON ON ON
Minimum 100msec
SEQ1 / 2F
SEQ2 / 2F
SEQ1 / 1F
SEQ3 / 2F
SEQ3 / 1F
Sequence 1
Sequence 3 Sequence 2
Time