APPENDIX B - PARAMETERS BASED ON APPLICATION
Application Parameter Code
DRV Group
When you want to change the frequency setting DRV-00
When you want to change the acceleration and deceleration time of the motor DRV-01, DRV-02
When you want to change the run/stop method DRV-03
When you want to change the frequency reference source DRV-04
When you want to set the multi-function DRV-005 ~ 07
When you want to see the output current, motor speed and the DC link voltage of inverter DRV-08 ~ 10
When you want to see the output voltage, output power, output torque from the user display DRV-11
When you want to check the fault of the inverter DRV-12
FU1 Group
When you want to use the Jump Code FU1-00
When you want to prevent the motor from rotating at opposite directions FU1-03
When you want to select the acceleration and deceleration pattern suitable for your application FU1-05 ~ 06
When you want to change the stopping method FU1-07
When you want to change the stopping accuracy for steady stop FU1-08 ~ 11
When DC injection braking is required before starting FU1-12 ~ 13
When you want to set the maximum frequency and the base frequency according to the rated torque of the
motor
FU1-20 ~ 21
When you want to adjust the starting frequency
FU1-22
When you want to limit the mechanical rotating speed to a fixed value FU1-23 ~ 25
When a large starting torque is needed for loads such as elevators (Manual/Auto Torque Boost) FU1-26 ~ 28
When you want to select an appropriate output characteristic (V/F characteristic) according to loads FU1-29
When you want to se up your own V/F pattern FU1-30 ~ 37
When you want to adjust the output voltage of the inverter FU1-38
When you want to use the energy saving function FU1-39
When you want to protect the motor from overheating FU1-50 ~ 53
When you want to output a signal when the overload condition lasts more than a fixed amount of time FU1-54 ~ 55
When you want to cut off the output when the overload condition lasts more than a fixed amount of time FU1-56 ~ 58
When you want to set the stall prevention function FU1-59 ~ 60
FU2 Group
When you want to check the fault history of the inverter FU2-01 ~ 06
When you want to use dwell function FU2-07 ~ 08
When you want to prevent the resonance from the oscillating characteristics of a machine FU2-10 ~ 16
When you want to protect inverter from input/output phase loss FU2-19
When you want to start the inverter as soon as the power is turned ON FU2-20
When you want to restart the inverter by resetting the fault when a fault occur FU2-21
When you want to use the instant power failure restart function (Speed Search)
FU2-22 ~ 25
When you want to use the retry function FU2-26 ~ 27
When you want to enter the motor constants FU2-30 ~ 37
When you want to reduce noise or leakage current by changing the PWM carrier frequency FU2-39
When you want to change the control method (V/F, slip compensation, PID, or sensorless operation)
FU2-40