HP (Hewlett-Packard) 30 HP30 Projector User Manual


 
i
USER SELECTION GUIDE (ACtionMaster SPECIFICATIONS)
230V Class (1 ~ 30HP)
Model Number
SV xxx ACtionMaster - 2
008 015 022 037 055 075 110 150 185 220
HP 1 2 3 5 7.5 10 15 20 25 30 Motor
Rating
1
kW 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Capacity
2
[kVA] 1.9 3.0 4.5 6.1 9.1 12.2 17.5 22.9 28.2 33.5
FLA [A] 5 8 12 16 24 32 46 60 74 88
Frequency 0 ~ 400 Hz (0-120Hz for Vector control)
Output
Ratings
Voltage 200 ~ 230 V
3
Voltage 3 Phase, 200 ~ 230 V (± 10 %) Input
Ratings
Frequency 50 ~ 60 Hz (±5 %)
Braking Circuit On the Board On the Board
On the Board
(Optional Resistor)
Optional (Braking Unit, Resistor)
4
Average Braking
Torque
100% 100% 150% 150%
Max. Continuous
Baking Time
5 seconds 5 seconds 15 seconds Controlled by Braking Unit
5
Dynamic
Braking
4
Max. Duty 3 % ED 2 % ED 5 % ED 5 % ED
Weight [lbs] 10.1 10.1 10.6 10.8 16.5 17.0 30.4 31.5 42.8 44.1
460V Class (1 ~ 30HP)
Model Number
SV xxx ACtionMaster - 4
008 015 022 037 055 075 110 150 185 220
HP 1 2 3 5 7.5 10 15 20 25 30 Motor
Rating
1
kW 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Capacity
2
[kVA] 1.9 3.0 4.5 6.1 9.1 12.2 18.3 22.9 29.7 34.3
FLA [A] 2.5 4 6 8 12 16 24 30 39 45
Frequency 0 ~ 400 Hz (0-120Hz for Vector control)
Output
Ratings
Voltage 380 ~ 460 V
3
Voltage 3 Phase, 380 ~ 460 V (± 10 %) Input
Ratings
Frequency 50 ~ 60 Hz (±5 %)
Braking Circuit
On the Board On the Board
On the Board
(Optional Resistor)
Optional (Braking Unit, Resistor)
4
Dynamic
Braking
4
Max. Braking Torque 100% 100% 150% 150%
1
Indicates the maximum applicable capacity when using a 4 Pole motor.
2
Rated capacity ( 3*V*I) is based on 220V for 200V class and 440V for 400V class.
3
Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage may be programmed.
4
1~5 HP inverters have internal braking resistors as standard. 7.5~10 HP inverters utilize optional braking resistors.