7-1
CHAPTER 7 - OPTIONS
The ACtionMaster series inverter provides many options for various applications. See the following option table and select
the proper options according to your application.
Option Name Description
Sub-A Board
(Extended I/O)
Extended I/O Module
Three Multi-Function Inputs (P4, P5, P6)
Three Multi-Function Outputs (Q1, Q2, Q3)
Auxiliary Analog Frequency Reference (V2)
LM (Load Meter) Output (0 ~ 10V)
Sub-B Board
(Speed Feedback)
Encoder Pulse Input – Speed Feedback (AOC, BOC / A+, A-, B+, B-)
Encoder Pulse Output (FBA, FBB)
Vector control (PG operation) and reference freq via pulse input
Sub-C Board
(Extended I/O)
Extended I/O Module
Three Multi-Function Inputs (P4, P5, P6)
One Multi-Function Outputs (Q1)
Isolated Auxiliary Analog Frequency Reference (V2)
Two Isolated Analog Meter Output (AM1, AM2)
Sub Boards
Sub-D Board
(Extended I/O, Speed
Feedback)
Extended I/O Module
Three Multi-Function Inputs (P4, P5, P6)
Two Multi-Function Outputs (Q1, Q2)
Auxiliary Analog Frequency Reference (V2)
Encoder Pulse Input – Speed Feedback (AOC, BOC / A+, A-, B+, B-)
Encoder Pulse Output (FBA, FBB)
Device Net
Embedded DeviceNet protocol
CAN Controller
Inverter Connection: Max. 64
Input Voltage: DC 11 ~ 25V
Baud Rate: 125, 250, 500k bps
CSMA/CD-NBA Method
PLC Communication
(F-Net)
Connection with Fnet Communication Module for GLOFA PLC
Inverter Connection: Max. 64
Baud Rate: 1M bps
Token Method
RS-485
RS-485 Communic ation
Inverter Connection: Max. 32
Baud Rate: Max. 19200 bps
Internal Installation
Option
Boards
Profi-Bus
Connection to ProfiBus Network
Device Type: Profibus DP Slave
Inverter Connection: Max. 64
Baud Rate: Max. 12M bps
LCD
32-Character Display
Download and Upload from the Keypad
External
Installati
on
Keypad
7-Segment
Six Digit 7-Sengment Display