HP (Hewlett-Packard) AD117-9003A-ED3 Server User Manual


 
Power Supply Unit
600 W output power
Front-end block (the actual power supply case) that converts the line voltage into a high DC
voltage.
Back-end voltage regulation modules (on the system board) that step down the front-end
DC voltage to the required voltages
Redundant and hot-pluggable power supplies (front-end block only)
System Board Manageability
Baseboard Management Controller (BMC)
Temperature monitoring and fans regulation by BMC
BMC manageability console shared with server console and general purpose serial port
IPMI protocol for communication between BMC/server/MP hardware
BMC hardware diagnostics display on the front status panel
E-buzzer remote hardware diagnostics on phone lines for support
Locator front/rear LEDs
Field replacement units monitoring by BMC
Serial port for local and modem console
Wake-on-LAN and Alert-on-LAN capabilities from the 10/100/1000 BT LAN port
Enhanced Server Manageability Using the Integrated Lights Out Management
Processor
The integrated Lights Out Management Processor (iLO MP) provides the following enhancements
to server manageability:
Web-based graphical user interface (GUI)
LAN telnet console
Web console
Serial port for local console
Serial port for modem console
Duplication of console screen content across all consoles
VGA and 2 D graphics display
Advanced Features:
Secure Shell (SSH) access
Group actions through the HP Systems Insight Manager (HP SIM)
Directory-based authentication and authorization (LDAP)
Hard Drives
The server supports the following hard drives:
36 GB 15K hot-plug Ultra320 SCSI drive
73 GB 15K hot-plug Ultra320 SCSI drive
146 GB 10K hot-plug Ultra320 SCSI drive
300 GB 10K hot-plug Ultra320 SCSI drive
The server holds up to three hard drives.
System Board Components
This section provides a block diagram of the system board and descriptions of key components
(integrated circuits) on the board. Figure 1-4 shows a block diagram of the server.
System Board Components 21