HP (Hewlett-Packard) AD117-9003A-ED3 Server User Manual


 
Figure 4-57 Reinstalling the Power Connectors
9. Replace the following server components:
PCI card cage. See “Replacing the PCI Card Cage” (page 72)
Server fans. See “Replacing a Server Fan” (page 48)
Processors. See “Replacing a Processor” (page 65)
Processor airflow guide. See “Replacing the Processor Airflow Guide” (page 56)
Memory DIMMs. See “Installing DIMMs” (page 59)
Memory airflow guide. See “Replacing the Memory Airflow Guide” (page 54)
10. Replace the top metal cover. See “Replacing the Top Metal Cover” (page 44).
11. Reconnect all of the power and external cables.
12. Power on the server. See “Powering On the Server” (page 38).
13. Boot to EFI.
14. Respond YES to prompts regarding copying information onto the new I/O baseboard.
Primary system ID values are undefined.
Do you want to copy the valid system ID values to the new board? (y/[n])
Y
15. Enter service mode.
Shell> sysmode service
Current System Mode: ADMIN
You are now in SERVICE mode.
16. Use the sysset command to enter the product data:
Shell> sysset prodname "server rx2620"
17. Use the syssetcommand to verify all values are set:
Shell> sysset
System Information:
Manufacturer: hp
Product Name: server rx2620
Product Number: AB332A
Secondary Product Number is Identical
Serial number: US51884101
Secondary Serial Number is Identical
86 Removing and Replacing Components