HP (Hewlett-Packard) S Server User Manual


 
Powering On and Starting the System
HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001
8-6
Power-On Procedure Using AC Power Cords
Power-On Procedure Using AC Power Cords
1. Find the detachable AC power cords included with your system. See Figure 8-3.
AC power cords for enclosures without power shelves are packaged in one of
the boxes included with your system.
AC power cords for enclosures with power shelves are preconnected to the
power shelves in the enclosures.
The AC power cord plugs vary depending on the country to which the system is
shipped. For AC power cord plug types and part numbers, see the Part Numbers topic
of the Service Information section of the NTL Support and Service Library on
page xxiv.
1. For each enclosure in the system, plug one end of a detachable AC power cord
into the appropriate receptacle on the system enclosure:
For enclosures that do not have power shelves:
a. Start with the group 01 processor enclosure.
b. Ensure the power interlock on the PMF CRU or IOMF CRU in slot 50 or 55
is fully engaged so that the power cord retainer is aligned with the power
receptacle.
c. Connect the AC power cord to the power receptacle on the PMF CRU or
IOMF CRU as shown in Figure 8-4.
d. Using a stubby Phillips screwdriver, secure the AC power cord plug in the
power cord retainer by tightening the retainer screw.
e. Repeat Step b through Step d for the other AC power cord for this
enclosure and for all remaining enclosures that do not have power shelves.
Figure 8-3. AC Power Cord
Caution. Do not plug the other end of the AC power cord into the dedicated outlet at this time.
Doing so immediately powers on the PMF CRU or IOMF CRU.
VST982.vsd