HP (Hewlett-Packard) S Server User Manual


 
Troubleshooting
HP NonStop S-Series Hardware Installation and FastPath Guide—541880-001
D-9
Any Amber LED Remains Lit After POST
Any Amber LED Remains Lit After POST
A fault might have been detected, or the component might not have been correctly
initialized and configured:
1. Check that the power-on cables are properly connected.
2. Repeat the power-on procedure.
3. Unseat and reseat the component.
4. If necessary, replace the component using the procedures on the Support and
Service Library.
5. If you cannot determine the cause of the problem, contact your service provider.
Yellow ServerNet Port LEDs on SEBs or MSEBs Are Not Lit
No corrective action is necessary. These LEDs are not used.
Group Service LED on System Enclosure Is Flashing
Check the group ID switch settings for all enclosures in the system. Settings for the two
switches within an enclosure must match, but two different enclosures must not have
the same group ID settings. If necessary, change the group ID switch settings using
the information about adding a processor enclosure in the NonStop S-Series System
Expansion and Reduction Guide.
The group service LED might have been activated manually using the OSM or TSM
package. To deactivate the LED:
1. Log on to the OSM Service Connection or TSM Service Application.
2. In the Tree pane, right-click the Group for that system enclosure.
3. Select Actions.
4. In OSM, select Set Service LED State, click Perform action, and select Off.
In TSM, select Clear Group Service LED and click Perform action.
Correcting Topology Attribute
If the value for the Topology attribute is Tetra 16 or error, use the OSM or TSM
Low-Level Link to:
Reset the Topology attribute: before system discovery, click System Actions.
Power off the system: before system discovery, click System Power Off.
Power on the system.
Ensure that the fans are turning and that the POSTs have finished.
If any system enclosure remains not visible in the Physical view, contact your service
provider.
You can reset the Topology attribute and power off the system before or after system
discovery. See the OSM or TSM Low-Level Link online help.