207
C Regulatory Specifications
Regulatory and Environmental Specifications
Environmental Specifications
Operating temperature 10 °C to 35 °C (50 °F to 95 °F). See Altitude exception.
Nonoperating temperature -40 °C to 70 °C (-40 °F to 158 °F).
Altitude 0 to 3048 m (0 to 10000 ft.). Note: Maximum ambient temperature is
linearly de-rated between 1520 m (5000 ft.) and 3050m (10000 ft.) by
1°C per 305 m (1000 ft.).
Operating humidity 85%, noncondensing at 40 °C (104 °F).
<33°C (91.4 °F) wet bulb at 40 °C (104 °F) without peripherals.
Nonoperating humidity 95%, noncondensing at +55 °C (131 °F).
Safety UL 1950, CSA 950, IEC 950, TUV EN60 950, NEMKO.
Emissions Certified to FCC Class A; tested to CISPR 22B, EN 55022, and registered
with VCCI.
Immunity Verified to comply with EN 50082-2.
Electrostatic discharge (ESD) Tested to ESD levels up to 20 kilovolts (kV) air discharge without physical
damage as per Intel environmental test specification.
Acoustic Sound pressure: <57 dbA at ambient temperatures. <28 °C measured at
bystander positions in operating mode.
Sound power: <6.5 BA at ambient temperatures. <28 °C in operating
mode.
Declaration of the Manufacturer or Importer
We hereby certify that this product is in compliance with EU EMC Directive 89/336/EEC and the
Low Voltage Directive 73/23/EEC.
Safety Compliance
USA/Canada: UL 1950, 3rd Edition/CSA 22.2, No. 950-M93, 3rd Edition.
Europe: TUV to EN60950 2nd Edition with Amendments, A1 + A2 + A3 + A4.
International: CB Certificate and Report to IEC 950, 2nd Edition w/ A1 + A2 + A3 + A4
and national deviations, including EMKO-TSE (74-SEC) 207/94.