Interphase Tech 5536 Network Card User Manual


 
Understanding LoopTest Messages
160 Interphase Corporation
Test failed The connection between the two ISDN B channels
could not be established before time-out because
another application answered the call. The Remote
Access Server was probably running when the test
started. To restart the test:
1. From the Start menu, select Programs, then
Administrative Tools (Common), and then
Remote Access Admin.
2. From the Server menu, select Stop Remote Access
Service.
3. Launch LoopTest again as described in Testing the
ISDN Line on page 154.
ERROR: The
pattern does not
arrive on the
other end
OR
ERROR: A bad
pattern has been
received: frame
<number>
When the connection is established, the test sends a
pattern on one B channel, and should receive it on the
other B channel. This message occurs when the pattern
is lost or invalid. Possible causes are:
The test application might be connected to another
application.
The ISDN number might be wrong.
An incoming call from another application arrived
and was answered by LoopTest.
The line or the network is defective.
Test aborted This message is displayed with an ISDN standard
clearing cause.
The corrective actions depend on the displayed cause.
(For example, check your ISDN number if No user
response or Incomplete Address messages appear.)
Message Cause