Magnetek Quattro DC Elevator Drive Computer Hardware User Manual


 
Quattro DC Analog Outputs C4 Submenu
Any value over 100% will cause the analog
channel to saturate.
Description
Analog Outputs C4 submenu
With a gain of 1.0 and an offset of 0.0, 10V will
indicate 100% or full value based on
programmed values. For example, with the
above scenario of a gain of 1.0 and an offset of
0.0, a 10V signal an Analog Output set to arm
current would indicate 100% of rated current.
Whereas a 0V signal on the same Analog
Output would indicate 0% of rated current.
Parameter Default
Hidden
Item
Run
lock
out
ANALOG OUTPUT 1
analog output #1 SPEED REF Y Y
ANALOG OUTPUT 2
analog output #2 SPEED FEEDBK Y Y
choices description D/A units
arm current (Motor Armature Current) Measured motor armature current % rated current
arm voltage (Motor Armature Voltage) Measured motor armature voltage % of rated volts
aux torq cmd
(Auxiliary Torque Command) Additional torque command from
auxiliary source
% rated torque
bus voltage (DC Bus Voltage Output) Measured DC bus voltage % of peak in
est motor spd (Estimated Motor Speed) Estimated speed of the motor RPM
field current (Motor Field Current) Measured motor field current % of rated (Full Field)
iarm error
(Armature Current Error) Measures the difference between the
reference current and the measured current
Amps
pretorque ref (PreTorque Reference) Pre-torque reference % base torque
motor mode -
(Motor Mode) Voltage level switches to indicate the mode the
current regulator is operating in.
1) Forward motoring (~ 9.7V)
2) Forward regeneration (high CEMF) (~ 4.4V)
3) Forward plugging (regeneration at low CEMF) (~ 1.3V)
4) Reverse plugging (regeneration at low CEMF) (~ -1.3V)
5) Reverse regeneration (high CEMF) (~ -4.4V)
6) Reverse motoring (~ -9.7V)
spd rg tq cmd
(Speed Regulator Torque Command) Torque command from
speed regulator
% base torque
speed command (Speed Command) Speed command before S-Curve % rated speed
speed error (Speed Error) Speed reference minus speed feedback % rated speed
speed feedbk (Speed Feedback) Speed feedback used by speed regulator % rated speed
speed ref (Speed Reference) Speed reference after S-Curve % rated speed
tach rate cmd
(Tachometer Rate Command) Torque command from tach rate
gain function
% base torque
tach speed
(Tachometer / Encoder Speed) Bi-directional signal representing
velocity measured by the encoder.
ft/min or m/sec
torque ref (Torque Reference) Torque reference used by vector control % base torque
Table 1 : Analog Outputs C4 Submenu2
65