Magnetek Quattro DC Elevator Drive Computer Hardware User Manual


 
Quattro DC Quick Parameter Reference
Sub
menu
Parameter Units Range Default
Site
Setting
C1
User Switches C1 Submenu continued …
C1 PreTorque SOURCE none
none
analog Input
serial
NONE
C1 PreTorque LATCH
none
not latched
latched
NOT LATCHED
C1 PTorq LATCH CLCK
none
serial
external tb
EXTERNAL TB
C1 FAULT RESET SRC none
external tb
serial
automatic
EXTERNAL TB
C1 OVERSPD TEST SRC
none
external tb
serial
EXTERNAL TB
C1 BRAKE PICK SRC
none
internal
serial
INTERNAL
C1 BRAKE PICK CNFM none
none
internal time
external tb
NONE
C1 BRAKE HOLD SRC
none
internal
serial
INTERNAL
C1 RAMPED STOP SEL
none
none
ramp on stop
NONE
C1 RAMP DOWN EN SRC none
external tb
run logic
serial
EXTERNAL TB
C1 BRK PICK FLT ENA
none
disable
enable
DISABLE
C1 BRK HOLD FLT ENA
none
disable
enable
DISABLE
C1 EXT TORQ CMD SRC none
none
analog input
serial
NONE
C1 DIR CONFIRM
none
disable
enable
DISABLE
C1 S-CURVE ABORT
none
disable
enable
DISABLE
C1 ENCODER FAULT
none
disable
enable
ENABLE
C1 PRIORITY MESSAGE
none
disable
enable
ENABLE
C1 STOPPING MODE
none
immediate
ramp to stop
IMMEDIATE
C1 AUTO STOP
none
disable
enable
DISABLE
C1 DSPR ENABLE
none
disable
enable
DISABLE
7