National Instruments 653X Switch User Manual


 
Chapter 3 Timing Diagrams
653X User Manual 3-20 ni.com
Figure 3-16. Level ACK Input Timing Diagram
Parameter Description Minimum Maximum
Input Parameters
t
rr*
REQ pulse width 75
t
r*r
REQ inactive duration 75
t
ar
ACK to next REQ 0
t
dir(1)
Input data setup to REQ active
(with REQ-edge latching)
0
t
rdi
Input data hold from REQ active
(with REQ-edge latching)
10
t
dir(2)
Input data setup to REQ
(with REQ-edge latching disabled)
0
t
adi
Input data hold from ACK
(with REQ-edge latching disabled)
0
Output Parameters
t
aa*
ACK pulse width 225
t
ra*
REQ to ACK inactive 100 200
All timing values are in nanoseconds.
REQ
Input Data Valid
(REQ-edge
latching)
Input Data Valid
(REQ-edge
latching disabled)
t
r*r
t
ra*
t
dir(2)
t
adi
t
ar
t
aa*
t
rr*
t
rdi
t
dir(1)
ACK
ACK and REQ are shown as active high