National Instruments 653X Switch User Manual


 
Chapter 3 Timing Diagrams
653X User Manual 3-40 ni.com
Figure 3-37. Long Pulse Output Timing Diagram
Note
With REQ edge latching disabled (default), output data valid will hold t
rdo
ns after
the REQ edge with REQ edge latching enabled, that data will be held for at most t
rdo
ns
after the REQ edge deasserts.
Parameter Description Minimum Maximum
Input Parameters
t
rr*
REQ pulse width
75
t
r*r
REQ inactive duration
75
t
ar
ACK to next REQ
0
Output Parameters
t
aa*
ACK pulse width
125
1
t
r*do
REQ inactive to new output data
(with REQ-edge latching)
050
t
rdo
REQ to new output data
(with REQ-edge latching disabled)
0
t
doa
Output data valid to ACK
(with REQ-edge latching disabled)
25
1
t
aa*
(min.)
= 125 + programmable delay
REQ
Output Data Valid
(REQ-edge
latching)
Output Data Valid
(REQ-edge
latching disabled)
t
r*r
t
r*do
t
doa
t
ar
t
aa*
t
rr*
ACK
t
rdo
ACK and REQ are shown as active high