National Instruments PCI-6110E/6111E Switch User Manual


 
Chapter 3 Hardware Overview
PCI-6110E/6111E User Manual 3-8
©
National Instruments Corporation
In above-high-level analog triggering mode, the trigger is generated
when the signal value is greater than highValue, as shown in Figure 3-7.
LowValue is unused.
Figure 3-7. Above-High-Level Analog Triggering Mode
In inside-region analog triggering mode, the trigger is generated when
the signal value is between the lowValue and the highValue, as shown
in Figure 3-8.
Figure 3-8. Inside-Region Analog Triggering Mode
highValue
Trigger
highValue
Trigger
lowValue