National Instruments PCI-6110E/6111E Switch User Manual


 
Chapter 4 Signal Connections
©
National Instruments Corporation 4-19 PCI-6110E/6111E User Manual
Figure4-11 shows the timing for the hardware-strobe mode
EXTSTROBE* signal.
Figure 4-11. EXTSTROBE* Signal Timing
TRIG1 Signal
Any PFI pin can externally input the TRIG1 signal, which is available
as an output on the PFI0/TRIG1 pin.
Refer to Figures4-8 and4-9 for the relationship of TRIG1 to the DAQ
sequence.
As an input, the TRIG1 signal is configured in the edge-detection mode.
You can select any PFI pin as the source for TRIG1 and configure the
polarity selection for either rising or falling edge. The selected edge
ofthe TRIG1 signal starts the data acquisition sequence for both
posttriggered and pretriggered acquisitions. The 611
X
E supports
analog triggering on the PFI0/TRIG1 pin. See Chapter3,
Hardware Overview
, for more information on analog triggering.
As an output, the TRIG1 signal reflects the action that initiates a DAQ
sequence. This is true even if the acquisition is being externally
triggered by another PFI. The output is an active high pulse with a
pulsewidth of 25 to 50ns. This output is set to tri-state at startup.
t
w
t
w
V
OH
V
OL
t
w
= 600 ns or 5 µs