Omron C200HG Computer Hardware User Manual


 
474
Execution Conditions
Commands Responses
Single Multiple Single Multiple
OK --- OK ---
End Codes An end code of 14 (format error) will be returned if the length of the command is
incorrect.
An end code of 15 (entry number data error) will be returned if an incorrect
instruction mnemonic or TC number is used.
An end code of 16 (command not supported) will be returned if the specified
instruction doesnt exist in the program.
End code Contents
00 Normal completion
13 FCS error
14 Format error
15 Entry number data error
16 Command not supported
18 Frame length error
23 User memory protected
10-3-18 SV READ 2 –– R$
Reads the constant SV or the word address where the SV is stored. The SV that
is read is a 4-digit decimal number (BCD) written as the second operand for the
TIM, TIMH(15), CNT, CNTR(12), or TTIM(87) instruction at the specified pro-
gram address in the users program.
Command Format
x 10
0
x 10
0
@ R$
x 10
0
x 10
1
x 10
3
x 10
2
x 10
1
OP1 OP2 OP3 OP4 x 10
3
x 10
2
x 10
1
Node no. Program address
(BCD)
Mnemonic Timer/counter
(0000 to 0511)
TerminatorFCSHeader
code
Use all four characters to specify the timer or counter instructions mnemonic.
Add a space to the end of a TIM or CNT mnemonic to make it 4 characters long.
Instruction name
Mnemonic
TC number
OP1 OP2 OP3 OP4
range
TIMER T I M (Space)
0000 to 0511
HIGH-SPEED TIMER T I M H
COUNTER C N T (Space)
REVERSIBLE COUNTER C N T R
TOTALIZING TIMER T T I M
Response Format
x 16
0
@ R$
OP1 OP2 OP3 OP4 x 10
0
x 10
0
x 10
1
x 16
1
x 10
3
x 10
2
x 10
1
Node no. Header
code
End code Operand SV TerminatorFCS
Host Link Commands
Section 10-3