App
endix B IBM ProPrinte
r
X24 and IBM ProPrinter II Commands
ESC J
n
(
IBM ProPrinter X24
)
One line feed of n/180"
(
for
g
ra
p
hics
)
Hexadecimal code: 1B 4
A
n
n = 1 - 255
Prints the buffer and feeds the paper line feed.If the parameter
AGM : NO
has been
selected in the SETUP , the paper line feeds by n/216"; If the parameter
AGM : YES
has
been selected in the SETUP , the paper line feeds by n/180".
It also executes a carriage return, if the parameter
LF + CR : YES
has been selected in
the SETUP.
The value of
n
must be a multiple of 3 (minimum line feed). In 8-needle graphic printing,
the value 24/216" ensures that the lines meet perfectly.
ESC * m
n1 n2 AGM
(
IBM ProPrinter X24
)
Select Alternate Gra
p
hics Mode
(
AGM
)
Hexadecimal code: 1B 2A m n1 n2 ...
Allows the selection of 8 or 24-needle graphic mode when
AGM: YES
has been selected
during SETUP.
Parameter
m
defines the type of graphic printing resolution according to the following
table:
m
Horizontal Resolution
Needles used
Notes
0
60
8
same as ESC K
1
120
8
same as ESC L
2
120
8
same as ESC Y
3
240
8
same as ESC Z
4
80
8
CRT I
6
90
8
CRT II
32
60
24
ESC K, high resolution
33
120
24
ESC L, high resolution
38
90
24
CRT III
39
180
24
Triple density high resolution
40
360
24
Sextu
p
le densit
y
hi
g
h resolution
Parameters n1 and n2 give the amount of graphic data plus 1 (calculations as for othe
r
BIM commands).
Normal and high resolution graphics modes (8 and 24 needles respectively) have the same
corresponding bit/needle relationships as those described for the standard graphics mode
(see
previous section
).
The vertical dot density is 1/180 in.
Example:
box 8x8 dots with center point 2x2 dots, standard density, 8 dots / column
hex: 1B 2A 00 08 00 FF 81 81 99 99 81 81 FF