Paradyne 336x E1 Network Card User Manual


 
ACCULINK 336x E1 NTU
E-14 December 1996 3360-A2-GB20-20
Generic Interface Test Table, Generic
Interface MIB
The test table provides access to additional tests
(loopbacks and pattern tests) that are not in the interfaces
group of MIB II.
Generic Interface Test Table – “ifExtnsTestType”
Object (ifExtnsTestEntry 4)
This object is a control variable used to start and stop
operator-initiated tests on the interface. It provides the
capability to:
Start/stop the Send 32767 test pattern on the
network interface.
Start/stop the Send 1-in-8 test pattern on the
network interface.
Start/stop the Send QRSS/511 test pattern on a
synchronous data port.
Start sending a V.54 UP/DOWN code to the remote
unit for a synchronous data port.
Start/stop the Monitor 32767 test pattern on the
network interface.
Start/stop the Monitor QRSS/511 test pattern on a
synchronous data port.
Start/stop the DCLB/DTLB loopback test on a
synchronous data port.
The following object identifiers control tests on the
interface.
noTest – Stops the test in progress on the interface.
testFullDuplexLoopBack – Initiates a DCLB on the
interface. Only supported for the data ports.
testLoopDTLB – Initiates a DTLB on the interface.
Only supported for the data ports.
testMonQRSS – Initiates a Monitor QRSS test on
the interface. Only supported for the data ports.
testMon511 – Initiates a Monitor 511 test on the
interface. Only supported for the data ports.
testSendQRSS – Initiates a Send QRSS test on the
interface. Only supported for the data ports.
testSend511 – Initiates a Send 511 test on the
interface. Only supported for the data ports.
testSendV54Up – Sends a V54 Up code to the
remote unit. Only supported for the data ports.
testSendV54Down – Sends a V54 Down code to
the remote unit. Only supported for the data ports.
testSend32767 – Initiates a Send 32767 test on the
network interface.
testSend1in8 – Initiates a Send 1-in-8 test on the
network interface.
testMon32767 – Initiates a Monitor 32767 test on
the network interface.
Where these object identifiers are defined as follows:
noTest – OBJECT IDENTIFIER ::=
[wellKnownTests 0]
testFullDuplexLoopBack – OBJECT
IDENTIFIER ::= [wellKnownTests 1]
testLoopDTLB – OBJECT IDENTIFIER ::=
[wellKnownTests 2]
testMonQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 3]
testMon511 – OBJECT IDENTIFIER ::=
[wellKnownTests 4]
testSendQRSS – OBJECT IDENTIFIER ::=
[wellKnownTests 5]
testSend511 – OBJECT IDENTIFIER ::=
[wellKnownTests 6]
testSendV54Up – OBJECT IDENTIFIER ::=
[wellKnownTests 7]
testSendV54Down – OBJECT IDENTIFIER ::=
[wellKnownTests 8]
testSend32767 – OBJECT IDENTIFIER ::=
[wellKnownTests 11]
testSend1in8 – OBJECT IDENTIFIER ::=
[wellKnownTests 12]
testMon32767 – OBJECT IDENTIFIER ::=
[wellKnownTests 13]