Paradyne 336x E1 Network Card User Manual


 
ACCULINK 336x E1 NTU
4-10 December 1996 3360-A2-GB20-20
Alarms
The E1 NTU can be attached, either locally or
remotely, to an ASCII terminal or printer to display or
print alarm messages. The Communications (COM) port
can be used as the destination for Alarm Set and Alarm
Clear messages. This enables an ASCII terminal or printer
to monitor the E1 NTU for alarm conditions. Alarms can
also be displayed on a PC that is using a terminal
emulation package.
Each alarm message contains a customer identification
to indicate which remote E1 NTU is reporting an alarm.
For information about customer identification, refer to the
Displaying Unit Identity section in Chapter 3, Operation.
Possible alarm messages are as follows:
Continuous Loss Of Signal detected at the x
Interface (where x is either HDSL Network
Loop 1, HDSL Network Loop 2, or DTE).
Alarm Cleared. Loss of Signal condition at the x
Interface (where x is either HDSL Network
Loop 1, HDSL Network Loop 2, or DTE).
Continuous Out Of Frame condition detected at
the x Interface (where x is either Network or
DTE).
Alarm Cleared. Out of Frame condition at the x
Interface (where x is either Network or DTE).
Alarm Indication Signal received at the x
Interface (where x is either Network or DTE).
Alarm Cleared. Alarm Indication Signal at the x
Interface (where x is either Network or DTE).
An Excessive Error Rate has been detected at
the x Interface (where x is either Network or
DTE).
Alarm Cleared. An Excessive Error Rate at the x
Interface (where x is either Network or DTE).
Remote Alarm Indication signal received at the
x Interface (where x is either Network or DTE).
Alarm Cleared. Remote Alarm Indication signal
at the x Interface (where x is either Network or
DTE).
Loss of Multiframe alignment condition detected
at the x Interface (where x is either Network or
DTE).
Alarm Cleared. Loss of Multiframe alignment
condition at the x Interface (where x is either
Network or DTE).
Remote Multiframe Alarm received at the x
Interface (where x is either Network or DTE).
Alarm Cleared. Remote Multiframe Alarm at
the x Interface (where x is either Network or
DTE).
For 2-port and 4-port E1 NTUs,
Continuous Out Of Frame condition detected at
synchronous data port n (where n is the port
number).
Alarm Cleared. Out Of Frame condition at
synchronous data port n (where n is the port
number).
An Excessive Error Rate has been detected at
synchronous data port n (where n is the port
number).
Alarm Cleared. An Excessive Error Rate at
synchronous data port n (where n is the port
number).
If two alarm conditions are detected at once, the higher
priority alarm is reported. However, if an even higher
priority alarm is detected before the first alarm is cleared,
the later alarm is not reported. (The alarms listed above
are in priority order with the highest priority listed first.)
Alarms remain active until the alarm condition is
cleared. Also, an alarm clear message is only sent when
there are no other alarms active.
For information about alarm configuration options,
refer to the Alarm Configuration Options section in
Appendix C, Configuration Options.
For troubleshooting information, refer to the
Troubleshooting section on page 4-12.