Paradyne 336x E1 Network Card User Manual


 
Maintenance
4-233360-A2-GB20-20 December 1996
Monitoring Test Patterns
Use the Monitor command to monitor 32767, QRSS, or
511 test patterns.
This command provides the number of errors detected
in the test pattern (5 digits, maximum 99999).
To monitor a 32767, QRSS, or 511 test pattern,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
F1
Test:
Rlpbk Lpbk Ptrns
F2
F3
3. From the Patterns screen, select Mon.
F1
Patterns:
Abort Send Mon
F2
F3
4. From the Patterns Mon screen, press F1 for 32767,
F2 for QRSS, or F3 for 511.
F1
Patterns: Mon
32767 QRSS 511
F2
F3
If you monitor a 32767 pattern, skip Step 5.
5. From the Monitor screen, press the Function key
that corresponds to the port for which you want to
monitor a QRSS or 511 test pattern. Use the scroll
keys, if necessary.
F1
Monitor:
Name
Prt1 Prt2 Prt3
F2
F3
The Monitor screen appears with the error count.
If the maximum of 99999 is exceeded, OvrFlw
appears instead of the count. If the receiver loses
synchronization while the monitor is active, No
Sync appears.
Aborting Test Patterns
Use the Abort command to stop all test patterns or any
selected test pattern active on the E1 NTU.
To abort test patterns,
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
F1
Test:
Rlpbk Lpbk Ptrns
F2
F3
3. From the Patterns screen, select Abort.
F1
Patterns:
Abort Send Mon
F2
F3