Paradyne 336x E1 Network Card User Manual


 
ACCULINK 336x E1 NTU
E-18 December 1996 3360-A2-GB20-20
Table E-1
(3 of 4)
SNMP MIB to Front Panel Command Cross-Reference
Front Panel Command SNMP MIB Object
Test–>Lpbk–>DCLB–>Prt
n
Test–>Lpbk–>Abort–>DCLB–>Prt
n
Set IfExtnsTestType for port
n
to
testFullDuplexLoopBack
Set dsx1LoopbackConfig for port
n
to
noTest
Test–>Lpbk–>DTLB–>Prt
n
Test–>Lpbk–>Abort–>DTLB–>Prt
n
Set IfExtnsTestType for port
n
to
testLoopDTLB
Set dsx1LoopbackConfig for port
n
to
noTest
Test–>Ptrns–>Send–>QRSS–>Prt
n
Test–>Ptrns–>Abort–>Send–>Prt
n
Set IfExtnsTestType for port
n
to
testSendQRS
Set IfExtnsTestType for port
n
to
noTest
Test–>Ptrns–>Send–>32767
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testSend32767
Set ifExtnsTestType for NET E1 to
noTest
Test–>Ptrns–>Send–>1in8
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testSend1in8
Set dsx1SendCode for NET E1 to
dsx1SendNoCode
Test–>Ptrns–>Send–>511–>Prt
n
Test–>Ptrns–>Abort–>Send–>Prt
n
Set IfExtnsTestType for port
n
to
testSend511
Set IfExtnsTestType for port
n
to
noTest
Test–>Ptrns–>Mon–>QRSS–>Prt
n
Test–>Ptrns–>Abort–>Mon–>Prt
n
Set ifExtnsTestType for port
n
to
testMonQRSS
Set ifExtnsTestType for port
n
to
noTest
Test–>Ptrns–>Mon–>511–>Prt
n
Test–>Ptrns–>Abort–>Mon–>Prt
n
Set ifExtnsTestType for port
n
to
testMon511
Set ifExtnsTestType for port
n
to
noTest
Test–>Ptrns–>Mon–>32767–>NET
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testMon32767
Set dsx1SendCode for NET E1 to
dsx1SendNoCode
Cnfig–>Load Cnfig–>Save Set devConfigAreaCopy to desired choice(Active to Customer1, etc.)
Cnfig–>Activ–>Edit–>DTE–>DTE–>Frame Set/Display dsx1LineType for DTE E1 to
dsx1E1
or
dsxE1-CRC
Cnfig–>Activ–>Edit–>DTE–>DTE–>Coding Set/Display dsx1LineCoding for DTE E1 to
dsx1HDB3
or
dsx1AMI
Cnfig–>Activ–>Edit–>Port–>Prtn->Port Type Display rs232PortType for port
n
to
rs422
,
v35
, or
X.21
Cnfig–>Activ–>Edit–>Port–>Prt
n
–>TxClock Set/Display rs232SyncPortClockSource for port
n
to
internal
or
external
Cnfig–>Activ–>Edit–>NET–>NET Frame Set/Display dsx1LineType for NET E1 to
dsx1E1
or
dsxE1-CRC
Cnfig–>Activ–>Edit–>NET–>Mgmt Link Set/Display dsx1Fdl for NET E1 to
dsx1other
or
dsx1FDL-none