Table E-1
(4 of 4)
SNMP MIB to Front Panel Command Cross-Reference
Front Panel Command SNMP MIB Object
Cnfig–>Activ–>Edit–>Chan–>DTE–>Assign Set/Display dsx1FracNumber and dsx1FracIfindex for DTE E1
Cnfig–>Activ–>Edit–>Chan–>DTE–>TS16 Display dsx1SignalMode for DTE E1 to
none
or
bitOriented
or
messageOriented
Cnfig–>Activ–>Edit–>Chan–>Prt
n
–>Assign To
Cnfig–>Activ–>Edit–>Chan–>Dsply
Set/Display dsx1FracNumber and dsx1Fracifindex for DTE E1 or
NET E1
Cnfig–>Activ–>Edit–>Chan–>Prt
n
–>Port Rate Display rs232PortInSpeed or rs232PortOutSpeed for port
n
Cnfig–>Activ–>Edit–>Gen–>Pri Clk Src
Cnfig–>Activ–>Edit–>Gen–>Sec Clk Src
Display dsx1TransmitClockSource for DTE E1 or NET E1 (Displays
the active clock only)
Cnfig–>Activ–>Edit–>User–>Com Rate
Cnfig–>Activ–>Edit–>User–>Aux Rate
Set/Display rs232PortInSpeed or rs232PortOutSpeed for COM or
AUX port
Cnfig–>Activ–>Edit–>User–>Char Length Set/Display rs232AyncPortBits for COM port
Cnfig–>Activ–>Edit–>User–>CParty Set/Display rs232AyncPortParity for COM port
Cnfig–>Activ–>Edit–>User–>CStop Bits Set/Display rs232AyncPortStopBits for COM port