Paradyne 336x E1 Network Card User Manual


 
Operation
3-193360-A2-GB20-20 December 1996
Selecting the Number of Trap Managers
If you intend to issue traps to an SNMP manager(s)
from this device, you must specify the number of SNMP
managers that are to receive the traps.
To specify the number of SNMP managers to receive
traps from this device,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
SNMP selection appears on the screen.
5. Select SNMP.
F1
Edit:
User Alarm SNMP
F2
F3
6. From the SNMP Config screen, select Trap.
F1
SNMP Config:
Gen Trap
F2
F3
7. Select the number of SNMP managers to receive
traps (from 1 through 6) by using the appropriate
Function key. Use the scroll keys, if necessary.
F1
Num Trap Mgrs:1
Next 1 2
F2
F3
Configuring a Destination for SNMP Traps
A destination must be configured for each SNMP trap
manager specified. This configuration option is displayed
for the number of trap managers specified by the Number
of Trap Managers configuration option.
To configure an IP address for the SNMP trap
manager,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
SNMP selection appears on the screen.
5. Select SNMP.
F1
Edit:
User Alarm SNMP
F2
F3
6. From the SNMP Config screen, select Trap.
F1
SNMP Config:
Gen Trap
F2
F3
7. Press F1 (Next) until the Trapn IP Address
configuration option appears.
8. Press F2 (Edit) to edit the IP address. You have the
option of using F3 (Clear) to reset the IP address
to the factory default 000.000.000.000. Refer to
the Setting the IP Address section on page 3-15 for
more information on setting an IP address.