Paradyne 336x E1 Network Card User Manual


 
ACCULINK 336x E1 NTU
3-34 December 1996 3360-A2-GB20-20
Configuring for Network Timing
To configure for network timing,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
Gen selection appears on the screen.
5. Select Gen.
F1
Edit:
NET Chan Gen
F2
F3
6. Select the primary clock source. For network,
press F2 (note that network is also the default).
F1
Pri Clk Src:NET
Next NET DTE
F2
F3
NOTE
The procedure for configuring the
secondary clock source is similar
to the example shown above. For
more information on configuration
options, refer to Appendix C.
Configuring for External Timing
To configure 2-port and 4-port E1 NTUs for external
timing,
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied
into the Edit area by using the appropriate
Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
key until the
Gen selection appears on the screen.
5. Select Gen.
F1
Edit:
NET Chan Gen
F2
F3
6. Select the primary clock source. For external,
press the
key until the Ext selection appears
on the screen.
F1
Pri Clk Src:NET
Next NET DTE
F2
F3
7. Select Ext (external timing).
F1
Pri Clk Src:NET
Prt
n
Int Ext
F2
F3