Q-Logic FIRMWARE VERSION 7.4 Switch User Manual


 
3 – Event Messages
Fault Events
59060-05 A 3-3
A
HW_BAD_SEATING
Meaning: Blade is improperly seated.
HW_MP_ACCESS_CPU0
Meaning: The maintenance panel SPROM data accessed through CPU0 is
either inaccessible or invalid.
HW_MP_ACCESS_CPU1
Meaning: The maintenance panel SPROM data accessed through CPU1 is
either inaccessible or invalid.
HW_MP_DATA_MISMATCH
Meaning: The maintenance panel SPROMs accessed through CPU0 and
CPU1 are not identical.
HW_POWERUP_FAIL
Meaning: Blade never established initial communications.
HW_SENSOR_FAULT
Meaning: Hardware temperature/voltage sensors are not functional.
HW_UNSUPPORTED_BLADE
Meaning: Installed blade is unknown or not supported.
SENSOR_FAULT
Meaning: Power Supply blade reports an internal fault.
temp_sensor_TEMP
Meaning: The temperature sensor reading is out of range; it is too high.
temp_sensor can be BOARD_0, BOARD, BOARD_1, DS1780_0,
DS1780, DS1780_1, MAX1617_0, MAX1617, ASIC_0, ASIC,
MAX1617_1, ASIC_1, or MEZZ_BOARD.
voltage_sensor_HIGH
Meaning: The voltage_sensor voltage supply is out of range; it is too high.
voltage_sensor can be 1.55V, 2.5V, 1.5V, ASIC_1.8V, 1.25V, 1.8V,
3.3V, CPU_1.8V, 5V, 12V, ASIC_0_1.5V, or ASIC_1_1.5V.
voltage_sensor_LOW
Meaning: The voltage_sensor voltage supply is out of range; it is too low.
1.55V, 2.5V, 1.5V, ASIC_1.8V, 1.25V, 1.8V, 3.3V, CPU_1.8V, 5V,
12V, ASIC_0_1.5V, or ASIC_1_1.5V.