Q-Logic FIRMWARE VERSION 7.4 Switch User Manual


 
3 – Event Messages
Informative Events
59060-05 A 3-67
A
(I) (8400.002C) (Switch) (User login session session_ID user account_name has timed out)
Meaning: A user login session has ended because of inactivity.
(I) (8400.0036) (Switch) (Hotreset not permitted at this time, try again later)
Meaning: Conditions exist that will not allow a hotreset. Try again later.
(I) (8400.0037) (Switch) (VIEnable automatically set to False since MFSEnable has been set
to True)
Meaning: Setting the Set Config Port parameter MFSEnable to True
automatically sets the Set Config Port parameters VIEnable and
LCFEnable to False.
(I) (8400.0038) (Switch) (LCFEnable automatically set to False since MFSEnable has been
set to True)
Meaning: Setting the Set Config Port parameter MFSEnable to True
automatically sets the Set Config Port parameters VIEnable and
LCFEnable to False.
(I) (8400.0039) (Switch) (MFSEnable automatically set to False since VIEnable has been set
to True)
Meaning: Setting the Set Config Port parameter VIEnable to True
automatically sets the Set Config Port parameter MFSEnable to
False.
(I) (8400.003A) (Switch) (MFSEnable automatically set to False since LCFEnable has been
set to True)
Meaning: Setting the Set Config Port parameter LCFEnable to True
automatically sets the Set Config Port parameter MFSEnable to
False.
(I) (8400.003E) (Switch) (Readjusting TempMonitoringWarning from value C to value C)
Meaning: The temperature threshold at which the switch issues a warning
alarm is being changed.
(I) (8400.0040) (Switch) (Readjusting TempMonitoringFailure from value C to value C)
Meaning: The temperature threshold at which the switch issues a failure
alarm is being changed.
(I) (8400.0048) (Switch) (A CIM edit session has been canceled)
Meaning: A Common Information Model (CIM) edit session has been
cancelled.