3 – Event Messages
Alarm Events
3-42 59060-05 A
S
(A2003.0003) (Fan flow match - ALARM CLEARED)
Meaning: The opposing fan air flow condition has been corrected.
Action: None
(A2004.0001) (Secondary cpu_blade assuming control of system due to a failure of Primary
cpu_blade)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a SANbox 9000 switch.
Action: Investigate the former primary CPU blade for the cause of the
failure.
(A2004.0002) (Secondary cpu_blade assuming control of system due to an administrative
switchover)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a SANbox 9000 switch.
Action: None
(A2004.0003) (Secondary cpu_blade assuming control of system due to an opening of the
latch or removal of Primary cpu_blade)
Meaning: Control is transferring from the primary CPU blade to the
secondary CPU blade on a SANbox 9000 switch.
Action: None
(A3000.0001) (Temp overheat, sensor_name sensor reads value C - ALARM SET)
Meaning: The chassis temperature has reached a failure threshold.
Action: Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
(A3000.0002) (Temp sensor sensor_name on blade slot_number reads value C - ALARM
SET)
Meaning: The chassis temperature has reached a failure threshold.
Action: Check air flow, fan operation, and ambient temperature. If the
problem cannot be corrected, power down the switch.
(A3001.0001) (Temp overwarm, sensor_name sensor reads value C - ALARM SET)
Meaning: The chassis temperature has reached a warning threshold.
Action: Check air flow, fan operation, and ambient temperature.
(A3002.0001) (sensor name sensor has returned to normal range - ALARM CLEARED)
Meaning: The chassis temperature has returned to the normal range and the
alarm condition has been cleared.
Action: None