Q-Logic SANBOX2-8C/16 Switch User Manual


 
A – Command Line Interface
Set Config Command
A-34 59022-08 Rev. B
D
MFSEnable Multi-Frame Sequence bundling. Prevents (True) or
allows (False) the interleaving of frames in a
sequence. The default is True. Enabling MFSEnable
disables LCFEnable and VIEnable.
MSEnable Management server enable. Enables (True) or
disables (False) management server on this port. The
default is True.
NoClose Loop circuit closure prevention. Enables (True) or
disables (False) the loop’s ability to remain in the open
state indefinitely. True reduces the amount of
arbitration on a loop when there is only one device on
the loop. The default is False.
IOStreamGuard I/O Stream Guard. Enable (Enable) or disables
(Disable) the suppression of RSCN messages. I/O
Stream Guard should be enabled only for ports
connected to initiator devices. The default is Disable.
VIEnable Enables (True) or disables (False) VI preference
routing. The default is False. Enabling VIEnable will
disable MFSEnable.
PDISCPingEnable Enables (True) or disables (False) the transmission of
ping messages from the switch to all devices on a
loop port. The default is True.
Table A-9. Set Config Port Parameters (Continued)
Parameter Description