C – Messages
Switch Properties Dialog
C-6 59022-08 Rev. B
D
Out of range domain ID specified. Verify that all information is valid and retry
the configuration change. Consult the
documentation for valid configurations.
Valid domain IDs must be in the range 1 to
239, and must be unique within a fabric. If
the fabric contains SANbox with E_Port
switches, then all domain IDs must be in
the same range of sixteen values: 1…16,
17…32, and so on.
Received error in attempting to edit switch
configuration.
Or
Received error in attempting to save
switch configuration.
Or
Received error in attempting to activate
switch configuration.
Verify that the data is valid, that the user
has permissions to modify the
configuration on the switch, that the switch
is reachable in the fabric, and that the
fabric is reachable from the user’s
workstation, then retry the configuration
change.
Reset will complete shortly. There will be a
brief loss of connectivity with switch.
Wait for the switch to become reachable
again. This may take up to one minute.
The new domain ID specified is invalid.
Unable to apply invalid chassis/fabric ID
values
Verify that all information is valid and retry
the configuration change. Consult the
documentation for valid configurations.
Valid domain IDs must be in the range 1 to
239, and must be unique within a fabric. If
the fabric contains SANbox with E_Port
switches, then all domain IDs must be in
the same range of sixteen values: 1…16,
17…32, and so on.
Table C-4. Switch Properties Dialog Messages (Continued)
Message User Action