Q-Logic SANBOX2-8C/16 Switch User Manual


 
A – Command Line Interface
Set Config Command
A-38 59022-08 Rev. B
D
Table A-12. Set Config Zoning Parameters
Parameter Description
FC-SW-2
AutoSave
Available only when the FC-SW-2 Compliant parameter is
True, this parameter enables (True) or disables (False) the
saving of changes to active zone set in the switch’s permanent
memory. Refer to ”FC-SW-2 Compliant” on page A-36. The
default is True.
Disabling the Autosave parameter can be useful to prevent the
propagation of zoning information when experimenting with
different zoning schemes. However, leaving the Autosave
parameter disabled can disrupt device configurations should a
switch have to be reset. For this reason, the Autosave
parameter should be enabled in a production environment.
Default Visibility Enables (All) or disables (None) communication among the
switch’s ports/devices and the fabric in the absence of an
active zone set. The default is All.