A – Command Line Interface
Set Setup Command
A-50 59022-08 Rev. B
D
Examples The following is an example of the Set Setup SNMP command:
SANbox2 #> admin start
SANbox2 (admin) #> set setup snmp
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Eth0NetworkMask Ethernet subnet mask address.
Eth0GatewayAddress Ethernet IP address gateway.
AdminTimeout Specifies the amount of time in minutes the switch
waits before terminating an idle Admin session.
Zero (0) disables the time out threshold. The
default is 30, the maximum is 1440.
TempMonitoringWarning Warning temperature threshold in °C above which
a warning condition alarm is generated. The
default is 65 °C.
TempMonitoringFailure Failure temperature threshold in °C above which a
failure condition alarm is generated. The default is
70 °C.
TempFailurePortShutdown Enables (True) or disables (False) the switch’s
ability to place all ports down when the internal
temperature exceeds the failure threshold. The
default is False. If the temperature exceeds the
failure threshold, correct the problem, then reset
the switch to bring the ports back online.
UserAuthentication Enables (True) or disables (False) the enforcement
of account names and passwords for SANbox
Manager. The default is False.
LocalLogEnabled Enables (True) or disables (False) the saving of log
information on the switch. The default is True.
RemoteLogEnabled Enables (True) or disables (False) the recording of
the switch event log on a remote host that supports
the syslog protocol. The default is False.
RemoteLogHostAddress The IP address of the host that will receive the
switch event log information if remote logging is
enabled. The default is 10.0.0.254.
Table A-14. System Configuration Settings (Continued)
Entry Description