A – Command Line Interface
Show Command
A-62 59022-08 Rev. B
D
Class3FramesIn 0 PrimSeqErrors 0
Class3FramesOut 0 RxLinkResets 23
Class3Toss 0 RxOfflineSeq 45
Class3WordsIn 0 TotalErrors 26
Class3WordsOut 0 TotalLIPsRecvd 0
DecodeErrors 0 TotalLIPsXmitd 0
EpConnects 25 TotalLinkResets 77
FBusy 0 TotalOfflineSeq 59
FlowErrors 0 TotalRxFrames 0
FReject 0 TotalRxWords 0
InvalidCRC 0 TotalTxFrames 0
InvalidDestAddr 0 TotalTxWords 0
LIP_AL_PD_AL_PS 0 TxLinkResets 54
LIP_F7_AL_PS 0 TxOfflineSeq 14
LIP_F7_F7 0
The following is an example of the Show Switch command:
SANbox2 #> show switch
Switch Information
------------------
SymbolicName sw .108
SwitchWWN 100000c0dd00bc56
SwitchType SANbox2-8c/16
BootVersion V1.0.0.7-0 (Mon Nov 3 13:11:08 2003)
CreditPool 0
DomainID 19 (0x13)
FirstPortAddress 130000
FlashSize - MBytes 128
LogLevel Critical
MaxPorts 16
NumberOfResets 224
ReasonForLastReset PowerUp
SWImageVersion (1) - build date V4.0.0.0-17 (day month date time year)
SWImageVersion (2) - build date V4.0.0.0-17 (day month date time year)
ActiveImageVersion - build date V4.0.0.0-2 (day month date time year)
PendingImageVersion - build date V4.0.0.0-17 (day month date time year)
ActiveConfiguration default
AdminState Online
AdminModeActive False
BeaconOnStatus False
OperationalState Online
PrincipalSwitchRole False
BoardTemp (1) - Degrees Celsius 32