SMC Networks SMC8612XL3 F 1.0.1.3 Switch User Manual


 
SNMP C
OMMANDS
4-151
are sent. In order to configure the switch to send SNMP notifications,
you must enter at least one snmp-server host command. In order to
enable multiple hosts, you must issue a separate snmp-server host
command for each host.
•The snmp-server host command is used in conjunction with the
snmp-server enable traps command. Use the snmp-server enable
traps command to specify which SNMP notifications are sent globally.
For a host to receive notifications, at least one snmp-server enable
traps command and the snmp-server host command for that host
must be enabled.
Some notification types cannot be controlled with the snmp-server
enable traps command. For example, some notification types are
always enabled.
The switch can send SNMP version 1 or version 2c notifications to a
host IP address, depending on the SNMP version that the management
station supports. If the snmp-server host command does not specify
the SNMP version, the default is to send SNMP version 1 notifications.
Example
Related Commands
snmp-server enable traps (3-151)
snmp-server enable traps
This command enables this device to send Simple Network Management
Protocol traps (SNMP notifications). Use the no form to disable SNMP
notifications.
Syntax
[no] snmp-server enable traps [authentication | link-up-down]
authentication - Keyword to issue authentication failure traps.
link-up-down - Keyword to issue link-up or link-down traps.
The link-up-down trap can only be enabled/disabled via the CLI.
Console(config)#snmp-server host 10.1.19.23 batman
Console(config)#