To verify I/O fencing configuration
On one of the nodes, type:
# vxfenadm -d
I/O Fencing Cluster Information:
================================
Fencing Protocol Version: 201
Fencing Mode: SCSI3
Fencing SCSI3 Disk Policy: dmp
Cluster Members:
* 0 (galaxy)
1 (nebula)
RFSM State Information:
node 0 in state 8 (running)
node 1 in state 8 (running)
Removing permissions for communication
Make sure you completed the installation of VCS and the verification of disk
support for I/O fencing. If you used rsh, remove the temporary rsh access
permissions that you set for the nodes and restore the connections to the public
network.
If the nodes use ssh for secure communications, and you temporarily removed
the connections to the public network, restore the connections.
103ConfiguringVCS clusters for data integrity
Setting up disk-based I/O fencing manually