Appendix A: Interfaces
A-32
K1297-G20 Monitor User Manual
U
2B1Q
Interface Module
The U
2B1Q
interface module provides two connectors for line connection,
which are designated as follows:
H “LT A” or “LT M” (old: “to LT”)
H “NT/LT B” or “NT/LT N” (old: “to NT(LT)”)
Modes of Operation. To monitor lines with the U
2B1Q
interface module,
proceed as follows:
1. Deactivate the line concerned and separate it.
2. Connect the network to the socket labelled “LT A”/“LT M” and
connect the NT to the socket labelled “NT/LT B”/“NT/LT N”. The
interface module responds in the line like a U-repeater.