Repair the K1297 by Recovery Disk. To repair the K1297 by the recovery disk,
proceed as follows:
CAUTION. Make sure that the protocol tester and the external CD-RW drive
are both powered off!
1. Attach the SCSI cable of the CD-RW drive to the SCSI I/O BUS
connector of the instrument. The SCSI connector is located on the front
of the K1297 compact and on the rear of the K1297.
2. Turn on the CD-RW drive .
3. Insert the CD ROM labeled K1297, Recovery CD (Build XPe) into
the CD-RW drive.
4. Switch on the device. Press <Del>, when the initial BIOS screen
appears. This opens the BIOS Setup dialog.
5. Use the arrow keys to select the option BIOS FEATURES SETUP
and press <Enter>.
6. In the dialog that opens, verify the settings of the Boot Sequence
option. If the sequence A,C,SCSI is currently not selected, change it
using the <PgUp> / <PgDn> keys.
7. Press <ESC> to return to the previous dialog.
8. Press <F10> to SAVE & EXIT SETUP”.