VXI VX1420A Computer Hardware User Manual


 
STATus Subsystem
3–66
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
STATus:QUEStionable:CURRent:CONDition?
Queries the contents of the Current Condition register. A value of one in a bit
indicates the corresponding power supply is currently failing. Unused bits always
return a value of zero. Definition of the bits in this register can be found in
STATus:QUEStionable:CURRent? command.
Reading the register does not clear it.
There is no command associated with this query.
STATus:QUEStionable:CURRent:CONDition?
Parameter Query response
Not Applicable <NR1>
Not Applicable
None
None
Query: STAT:QUES:CURR:COND?
Response:0
STATus:QUEStionable:CURRent?
STATus:QUEStionable:CURRent:ENABle
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands