VXI VX1420A Computer Hardware User Manual


 
Getting Started
1–24
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
You can set the logical address of the mainframe with the switches on the rear
panel. Figure 1–15 shows the locations of the logical address switches on the
rear of the Enhanced Monitor panel.
In most cases, you can leave the switches in the factory default position of FF.
This allows the mainframe to dynamically configure the address. However,
make sure that no other module has the same slot address as the Enhanced
Monitor board. If all VXI modules in the mainframe are set to FF, the resource
manager will “dynamically” configure the module’s logical address. If a VXI
module is set to a logical address other than FF, you must be careful to choose a
unique address. See Enhanced Monitor Board Jumpers on page B–4 for
information on configuring the jumpers on the Enhanced Monitor board.
Figure 1–15: Logical address switches
Logical Address Switch
Settings