VXI VX1420A Computer Hardware User Manual


 
DISPlay Subsystem
3–28
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
DISPlay:WINDow:TEXT:DATA
DISPlay:WINDow:TEXT:DATA?
Sets or queries the user defined message to be displayed on the front panel
readout of the mainframe. You can display up to 60 characters in the message.
The string “SYSTEM OK” is the default factory message. This message only
displays when there are no monitor failures.
DISPlay[:WINDow]:TEXT[:DATA] <String>|<Block>
DISPlay[:WINDow]:TEXT[:DATA]?
Parameter Query response
<String>
<Block>
<String>
Not Applicable
–223, “Too Much Data”
You attempted to send too much data to the display.
–220, “Parameter Error”
You attempted to send nonprinting data in the block parameter.
None
Command: DISP:TEXT SYSTEM INIT"
Query: DISP:TEXT?
Response: SYSTEM INIT"
None
NOTE. (DISPlay:WINDow:TEXT:DATA): This command applies to all
VX1420A mainframes or VX1410A mainframes with Option 1M.
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands