VXI VX1420A Computer Hardware User Manual


 
STATus Subsystem
3–68
VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual
STATus:QUEStionable:CURRent:LEVel?
Queries the current power supply output amperage.
There is no command associated with this query.
STATus:QUEStionable:CURRent:LEVel? <Power Supply>
<Power supply> Query response
{P24 | P12 | P5 | N2 | N5PT2 | N12 | N24} <NR2>
Code Power supply
P24 +24V
P12 +12V
P5 +5V
N2 –2V
N5PT2 –5.2V
N12 –12V
N24 –24V
Not Applicable
–224, “Illegal Parameter Value”
You attempted to use an illegal parameter value.
None
Query: STAT:QUES:CURR:LEV? P5
Response: 5.11