Zebra 105SL User’s Guide 17
0HGLDDQG5LEERQ&DOLEUDWLRQ
Initially, you may want to try autocalibrating the printer rather than
proceeding with the full calibration procedure described below. To
autocalibrate the printer:
1. Load the media and ribbon.
2. Close the printhead. The printer autocalibrates.
If the media fails to load or an error occurs, then perform the steps listed
below.
NOTE: All steps must be performed in the following procedure,
even if only one sensor needs to be adjusted.
1. Press the SETUP/EXIT key.
2. Press the NEXT/SAVE key until “MEDIA AND RIBBON
CALIBRATE” displays.
3. Press the (+) key to start the calibration sequence. “LOAD BACKING
CANCEL CONTINUE” displays.
4. Open the printhead. Remove approximately 8" (200 mm) of labels
from the media roll, enough so that only the backing material is
threaded between the media sensors when the media is loaded
(refer to Figure 10).
Figure 10