18 Zebra 105SL User’s Guide
5. Press the (+) key. The front panel display shows “REMOVE
RIBBON CANCEL CONTINUE.”
6. Slide the ribbon as far from the printer frame as possible.
7. Close the printhead, trapping the ribbon in this position.
8. Press the (+) key. The front panel shows “CALIBRATING PLEASE
WAIT.”
9. When this part of the calibration process is completed, the display
reads “RELOAD ALL CONTINUE.”
10. Open the printhead. Pull the backing material until a label is
positioned between the media sensors.
11. Return the ribbon to its proper position.
12. Close the printhead. Press the (+) key to perform the next part of the
calibration sequence. “MEDIA AND RIBBON CALIBRATE”
displays. The printer is calibrated when the media stops feeding.
13. Press the SETUP/EXIT key to leave the programming mode. Choose
“permanent” when SAVE CHANGES displays.
14. Press the NEXT/SAVE key to save the changes.