A SERVICE OF

logo

Message Description Action
59.XYcontinued
PRINTER ERROR
alternates with
To continue
turn off then on
59.90 and 59.A0 Errors on control panel
59.09.00 (event log only)
59.10.00 (event log only)
An error occurred when the drum motor
started or while the drum motor was rotating.
1. The connectors in the drum motor drive
signal line are not connected properly.
Reseat the drum motor connector J5002
and the DC controller PCB connector J1019.
2. Faulty drum motor. Replace the drum
motor.
3. Faulty DC controller PCB. Replace the
DC controller PCB.
59.99.00 - (event log only)
An error occurred in the secondary transfer
engaging mechanism.
1. Faulty secondary transfer engagement
sensor. Replace the secondary transfer
engagement sensor.
2. Faulty secondary transfer engaging
solenoid. Replace the secondary transfer
engaging solenoid.
3. Faulty feed motor. Replace the feed
motor.
4. Faulty DC controller PCB
Action: Replace the DC controller PCB.
Table 7-3. Numerical printer messages (continued)
348 Chapter 7 Troubleshooting ENWW